I-C4C

The i-C4C is the latest generation of overload protection which, thanks to its advanced technology, can be used for the most complex applications.
Operation is fully digital and the unit is easy to install, configure and use.
The many possibilities of the device allow for a wide range of applications that extend far beyond load limiting alone. Thus, the device can also be used for weight indication, feedback to the remote control transmitter, wireless communication between cranes, processing of safety applications such as limit switches, anti-collision protection, gate protection and area protection, …

The i-C4C is available in 2 models: master and slave.
At least one master module is required for each application. The slave module takes care of the expansion of inputs and outputs, but also allows digital, analogue I/O and load cell information to be connected locally (e.g. to a hoist). The connection between the modules is done via CAN so that the cabling on the crane is enormously simplified.

The new generation of i-C4Cs also allows cloud storage and monitoring, using an external module.

Function Description
General
Operator Interface 2 x 16 character display *
Numeric keypad *
Status LEDs (System, Mobile, CAN, Wireless)
Fields of application Load limiting
Summation
Signal transmission (digital/analogue)
Weight indication
Protection applications (anti-collision, limit switch, area protection), tandem protection, …)
Electronics
Digital inputs 6 optically isolated inputs
Suitable for potential free contacts
Digital outputs 4 relays with changeover contacts
Galvanically isolated
Analogue inputs 1 analogue 0-10 Vdc
8 bit resolution
Analogue outputs 1 analogue 0-10 Vdc
8 bit resolution
Max. 10 mA
Interfaces 2 CANOpen fieldbus modules (125 kbits/s, 250 kbits/s)
1 USB
1 wireless PAN (option)
1 mobile phone (option)
Power supply 12 Vdc ± 10%
100 – 240 Vac (option)
Power Consumption Max. 7W
Mechanical
Dimensions 182 x 109 x 27 mm
Mounting 35 mm DIN
Weight 0.5 kg
Housing PC/ABS
Surroundings
Operational temperature -10 °C to +60 °C
Storage temperature -40 °C to +85 °C

* Only on the master module